Le low energy knowing act doors open when an activation device is engaged such as a push.
Stanley automatic doors stuck open.
If the door does not open close turn power off for 15 seconds then switch on.
On stanley automatic doors the power switch is the illuminated red switch typically found on the side of the door system jamb tube or on the underside of the header.
Check to confirm that the power switch is in the on position.
You will find our automatic sliding doors throughout north america and europe in a wide variety of locations including.
Our stanley automatic door is squeeking.
Check the battery on the transmitter if door is controlled remotely.
What makes this door system unique is the use of the bearing drive block rod and cable as most automatic sliding door systems are comprised of a rubber timing belt which moves along the dc motor pulley.
Doors are stuck in the same position and will not move.
Stanley automatic sliding doors are by far the most popular door system in america.
If the door is stuck open make sure it is not in the hold.
Or vice versa the door will open and close in the opposite direction.
When you turn on the power to the automatic doors do the automatic sliding doors open and then suddenly stop.
Check to make sure all transmitters have a fully energized 9 volt battery.
Overhead interior exterior sensor zones are clear and there are no items in the pathway of door for the following steps turn power off.
Secure door to its hanger by pushing door panels in from the outside.
If door does not open close turn power off for 15 seconds then switch on fe full energy doors open as soon as the motion sensor detects motion.
Today stanley access technologies proudly manufactures installs and services sliding swinging folding transit metro and revolving door systems as well as.
I used wd40 and it did not help.
Function switch is set to automatic aut.
Flip the automatic door control switch on the stanley automatic door operator header box to hold open confirm the door operator opens each time you do that.
Since receiving a patent for the world s first automatic door operator more than 80 years ago stanley has led the industry with state of the art manual and automatic door solutions.
If this is the case you know the problem is in the wireless handicap push button radio controls.
If the carrier wheels are the source of the squeaking clean the top track with glass cleaner or degreaser also make sure the carrier wheels are clean as well.
For knowing act push plate operators.
If the door is stuck open make sure it is not.
We also perform repairs and maintenance on all brands of automated doors.
Stanley access technologies manufactures state of the art automatic slide doors for industrial commercial healthcare and retail use.